Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS C-60 Serie Handbuch Seite 51

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

C60_1-029_0108_en.p65
25
Description of
Input Buffer
(continued)
Please note the
basic procedure on
15 and 30...34
and the examples on
pages
35...47.
26
Description of
Input Buffer
(continued)
Please note the
basic procedure on
15 and 30...34
and the examples on
pages
35...47.
26
E
Function Description
Input buffer, configuration and explanation
Sub-
Meaning
Function Description
address
01
Error code (continued)
Hex
09
Cable break to select read/write head, or head not connected.
Hex
0C
The EEPROM cannot be read/programmed.
Hex
0D
Faulty communication with the code tag.
Hex
0F
Contents of the 1st and 2nd bit header (1st and last bytes) of
Hex
the output buffers are not identical (2nd bit header must be
served).
13
Start address + number of bytes > memory range entered in the
Hex
initialization.
14
invalid max. number of write cycles entered in the initialization.
Hex
15
invalid memory size of the code tag entered in the initialization.
Hex
16
Max. 1 kB segment size exceeded.
Hex
17
Code tag incorrectly initialized (comparison with nominal data
Hex
with command identifier 09
18
Code tag not initialized. All bytes are still 00
Hex
or:
Configuration 1st byte
00
Default value (factory setting).
Hex
Changes depending on the configuration.
or:
Data
Data which was read from the code tag.
(continued on next )
Function Description
Input buffer, configuration and explanation
Sub-
Meaning
Function Description
address
02
Configuration 2nd byte
Hex
80
Default value (factory setting). Do not change!
Hex
or:
Data
Data which was read from the code tag,
or:
Warning
Memory management (details see page 9) signals:
56
Pre-warning (1,000 write cycles left).
Hex
45
End warning.
Hex
03
Configuration 3rd byte
Hex
00
Default value (factory setting).
Hex
Changes depending on the configuration.
or:
Data
Data which was read from the code tag.
04
Configuration 4th byte
Hex
82
Default value (factory setting).
Hex
Changes depending on the configuration.
or:
Data
Data which was read from the code tag.
05
Configuration 5th byte
Hex
00
Default value (factory setting).
Hex
Changes depending on the configuration.
or:
Data
Data which was read from the code tag.
06
Configuration 6th byte
Hex
00
Default value (factory setting). Do not change!
Hex
or:
Data
Data which was read from the code tag.
07
2nd Bit header The data are valid if the 1st and 2nd bit headers are in agreement.
Hex
or:
Data
Data which was read from the code tag.
does not bring agreement).
Hex
.
Hex
E
25

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bis c-6001Bis c-6021

Inhaltsverzeichnis