Herunterladen Inhalt Inhalt Diese Seite drucken

OSRAM e:cue LIGHTDRIVE+ Installationsanleitung Seite 28

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Setup Manual - LIGHTDRIVE+
Data backup time:
User interface
Fixture configuration:
Engine configuration:
Ethernet/e:net:
Ethernet connection:
DMX outputs:
DMX connections:
Digital inputs:
Digital inputs supply:
Low-side switches:
28
Max. 2 h via Gold Cap
8 Scene buttons
3 Zone buttons
1 Tone button
1 jog wheel with switch
with 3 x 2 DIP switches (1 ... 6)
with 4 DIP switches (7 ... 10)
10/100 MBit/s
Push-in spring connection plug
Stripping length: 6 mm
Major diameter of isolated cable max. 2 mm
Solid: cable cross-section: 0.14 ... 0.5 mm²
Flexible: cable cross-section: 0.2 – 0.5 mm²
Max. cable length: 65 m
2 x DMX512-A
Push-in spring connection plug
Stripping length: 6 mm
Major diameter of isolated cable max. 2 mm
Solid: cable cross-section: 0.14 ... 0.5 mm²
Flexible: cable cross-section: 0.2 – 0.5 mm²
2 x digital in, 5 V DC
Input high threshold voltage:
V
= 5 V
IHmin
Input low threshold voltage:
V
= 2 V
ILmax
Input voltage max.:
V
= 24 V
INmax
For potential-free contacts
V
= 5 V DC
SUP
max. 15 mA
typical current when sourcing all 2 ports:
I
= 12 mA
typ
Use 5 V DC from device (pin 7)
2, max. load 24 V DC, 4 A, Normally open