3.4.2 Water connection with BGS tap

1. First, screw in the special fittings with the cover plate to a ½" water connection onto a wall
and seal using a suitable sealant. Both ⅜" water connections must face vertically upwards.
2. Install pipe extensions with compression connectors according to installation diagram on
the mounting template. Determine the position of the appliance using the mounting tem-
plate and then dowel and fit wall bracket using screws.
3. Hook appliance onto wall bracket and insert pipe extensions into the water connections of
the appliance. Click appliance into place. Screw pipe extensions with compression connec-
tors to the appliance. Use a spanner to hold the instantaneous water heater water connec-
tions steady as you do so.
4. Fit sprayhead and screw to fitting.
5. After installation, carefully check all connections for leaks and rectify as necessary.
Fig. 7: "Installation with BGS tap"