9. Fault finding the product

DANGER
Electric shock
Death or serious personal injury
- Before starting any work on the product,
make sure that the power supply has
been switched off and that it cannot be
accidentally switched on.
WARNING
Corrosive liquids
Death or serious personal injury
- Wear personal protective equipment.
Fault
1.
The pump does not run.
2.
The motor-protective circuit
breaker has tripped. It trips
immediately when power
supply is switched on.
3.
The pump does not run.
4.
The motor-protective circuit
breaker trips occasionally.
5.
The motor-protective circuit
breaker has not tripped, but
the pump is inadvertently
out of operation.
12
Cause
a)
Supply failure.
b)
Motor protection has tripped.
c)
The control-current circuit is
defective.
a)
Contacts of the
motor-protective circuit
breaker or magnet coil are
defective.
b)
Cable connection is loose or
faulty.
c)
The motor winding is
defective.
d)
The pump is mechanically
blocked.
e)
The setting of the
motor-protective circuit
breaker is too low.
a)
The rotor is blocked.
a)
The setting of the
motor-protective circuit
breaker is too low.
b)
Periodic supply fault.
c)
Periodically low voltage.
a)
See 1. a, c and 2. d.
WARNING
Toxic liquids
Death or serious personal injury
- Wear personal protective equipment.
CAUTION
Hot or cold liquid
Minor or moderate personal injury
- Wear personal protective equipment.
Remedy
Switch on the switch.
Replace the fuse.
Check cables and cable connections
for defects and loose connections.
See 2. a, b, c, d, e.
Repair or replace the control-current
circuit.
Replace the contacts of the
motor-protective circuit breaker, the
magnet coil or the entire
motor-protective circuit breaker.
Check cables and cable connections
for defects, and replace the fuses.
Repair or replace the motor.
Switch off the power supply, and
clean or repair the pump.
Set the motor-protective circuit
breaker according to the rated
current of the motor (I
See the nameplate.
Switch off the power supply, and
clean or repair the pump.
See 2. e.
See 2. b.
Check cables and cable connections
for defects and loose connections.
Check that the power supply cable of
the pump is correctly sized.
).