Instruction Manual Electrobloc EBL 226 C +OVP
If an overload or an insufficiently charged living area battery causes the vol-
tage to fall so low that the automatic disconnector is triggered, any non-es-
sential consumers should be switched off.
If need be, the 12 V supply can begin operation for a short time. To do this,
switch on the 12 V main switch on the DT/LT ... control and switch panel.
However, if the battery voltage remains below 11.0 V, the 12 V power supply
can not be turned back on.
Fully charge the living area battery as soon as possible. For further informa-
tion, see "Battery voltages" in the instruction manual of the relevant DT/LT ...
control and switch panel .

Additional functions

4.2
Automatic switch
This relay supplies the AES/compressor refrigerator with power from the
function for
starter battery when the vehicle engine is running and the D+ connection is
AES/compressor
live. An AES/compressor refrigerator is powered by the living area battery
refrigerator
when the vehicle engine is not running.
Step fuse
The step output is protected by a self-resetting 15A fuse.
If a fault occurs, such as overcurrent, the self-resetting fuse interrupts the
relevant circuit.
After rectification of the fault, the fuse automatically resets after approx. 1
minute.
Battery charging with
Maximum permitted charge current 14 A, protected with 15 A
solar charging regulator
Depending on the solar charge regulator used, either only the living area
battery is charged or the living area battery and the starter battery.
Awning light
The power supply to the awning light is automatically interrupted as soon as
the engine is started and the D+ connection is live. The awning light can still
be used even if the 12 V power supply is switched off.
Tank heater
The tank heater is enabled via the DT/LT ... control and switch panel. The
tank heater can still be used even if the 12 V power supply is switched off.
Side marking lights
The side marking lights are switch on via the integrated relay. They are po-
wered from the start battery. The relay is activated via terminal 58.

Maintenance

5
The Electrobloc requires no maintenance.
Cleaning
Clean the electronic block with a soft, slightly damp cloth and mild detergent.
Never use spirit, thinners or similar substances. Do not allow liquids to enter