Starting up
the System
Flat vehicle fuses
Self-resetting
fuses
811.573 BA / EN
Instruction Manual Electrobloc EBL 226 C +OVP
DANGER!
Y
Incorrect setting of the battery selector switch.
Risk of explosion due to build up of explosive gases:
Set the battery selector switch to the correct position.
F
ATTENTION!
Y
Incorrect setting of the battery selector switch.
Damage to the battery.
Set the battery selector switch to the correct position.
F
Disconnect the electronic block from the mains before adjusting the bat-
tery selector switch.
Fig. 1
Battery selector switch
Set the battery selector switch (Fig. 1, Pos. 1) to the correct position
using a thin object (such as a ballpoint pen):
Lead gel battery: Set the battery selector switch to "Lead gel".
F
Lead acid battery: Set battery selector switch to "Lead gel".
F
Insert "+ solar cell" connector on the solar charge regulator.
Start up the system as described in section 3.1.
3.3

System Faults

A fault in the power supply system is usually caused by a blown fuse.
The following is protected with a self-resetting fuse:
Exit step
F
If a fault has occurred here, the step switch must not be pressed for about
one minute. This fuse resets automatically during this period.
Please contact our customer service department if you are unable to rectify
the fault using the following table.
If this is not possible, e.g. if you are abroad, you can have the electronic bloc
repaired at a specialist workshop. Please note that the warranty will become
void if incorrect repair work is carried out. Schaudt GmbH shall not accept
liability for any damages resulting from such repairs.