Herunterladen Inhalt Inhalt Diese Seite drucken

Error Messages - Multiplex Power Peak Twin EQ-BID 1000W Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

14.

ERROR MESSAGES

Power Peak® ® Quad EQ-BID is equipped with special safety features to ensure safe and
reliable charging and discharging operation. As soon as a fault occurs, a corresponding
message appears in the display and the piezo buzzer emits a shrill warning tone. After
eliminating the cause of the problem, the following error messages can be acknowledged/
erased by pressing the "ESC" button.
[
INPUT VOLTAGE
]
*The input voltage is 10.86 V
*Please check the Input vol-
tage!
[
NO BATTERY
]
*No Battery
is connected to the output.
[
REVERSE POLARITY
*The battery is connected
with reverse polarity to the
output!
[
BREAK
]
*The battery connection
is disconnected.
*Please connect the battery
and connect
[
DATA COMMUNICATION
*Contact the
Multiplex Service department.
Operating Instructions
Power Peak ® Twin EQ-BID
[
SHORT CIRCUIT
The output
has a short circuit
*Please check the Output!
[
VOLTAGE TOO LOW
*Output voltage is
lower than the
selected cell count or Voltage
]
[
VOLTAGE TOO HIGH
*Output voltage is
higher than the
selected cell count or Voltage
[
TEMPERATURE SENSOR
*The Temperature sensor
is reverse polarity or defective.
[
BID CHECK SUM
]
BID is defective,
press any button to initialise.
29
63
[
BATTERY TEMP. TOO LOW
]
*The battery temperature
is for safe operation too low!
[
BATTERY TEMP. TOO HIGH
]
]
*The battery temperature
is for safe operation too high!
]
[
INTERNAL TEMPERATURE
]
*The internal temperature
is too high!
[
WRITE BID DATA
]
*The Data will
not be stored
in the BID system.
*If this message
is displayed continuously,
replace the
BID System.
]
[EQUALIZER VOLTAGE TOO
HIGH]
Equalizer voltage
is too high.
# 30 8563
]
]

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

30 8563

Inhaltsverzeichnis