Base plate assembly
Install the middle rear cover with the
4 drill holes to fit the electric control to the column. Use the supplied
M6X10 screws
as shown in the adjacent diagram.
Electric control assembly
Fit the electric control to the column using the supplied screws as
shown in the adjacent diagram.
Check the nameplate to ensure that the motor is suitable for the
voltage available at the customer's premises.
Establish the electrical connections as shown in the circuit diagram
(point 6.2). Use the cables and lines supplied for this purpose.
Work must be carried out in accordance with local regulations. Make
sure that the phases are properly connected (direction of rotation)
and
the lift is properly grounded.
Filling the oil and venting
Use only the hydraulic oil specified in the operating instructions.
Open the oil filler cap and fill approx. 6 litres of hydraulic oil into the tank.
Pressing the LIFT button moves the lift upwards until the max. height
has been reached. Release the button when the maximum height has been reached, as otherwise
the electric motor or the gear pump may be damaged. Pressing the LOWER button moves
the lift right to the bottom. Keep holding the LOWER button for around 3 seconds after the
lift has reached its lowest point to allow any trapped air to escape.
Repeat this LIFT and LOWER procedure three times.
Warning: Attempting to test without oil or when the motor is rotating in the wrong direction can destroy
the
hydraulic pump.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03