8 Quick Start-up Guide for ACS850 with Standard Control Program
Select the motor control mode. DTC is suitable for
most cases.
Scalar mode is recommended if
• the nominal current of the motor is less than 1/6
of the nominal current of the drive,
• the drive is used for test purposes with no motor
connected, or
• the drive controls multiple motors and the number
of motors connected is variable.
Enter the motor data from the motor nameplate.
Asynchronous motor nameplate example:
3
690 Y
400 D
660 Y
380 D
415 D
440 D
Cat. no
Permanent magnet motor nameplate example:
3 ~ motor
S1 SPEC INSUL.
JK-21640-1
V
400 D
Prod. code
• motor nominal current
Allowed range: approximately 1/6 × I
the drive (0...2 × I
mode = Scalar).
Downloaded from
www.Manualslib.com
ABB Motors
motor
M2AA 200 MLA 4
IEC 200 M/L 55
No
Ins.cl. F
Hz
kW
r/min
A
V
50
30
1475
32.5
56
50
30
1475
50
1470
34
30
30
1470
59
50
1475
50
30
54
35
1770
59
60
3GAA 202 001 - ADA
6312/C3
6210/C3
ABB Motors
M2BJ 280SMB 10 B3
No 3424522
Ins.cl. F
Hz
kW
r/min
A
50
55
600
103
2GBJ285220-ADA405445477
6316/C3
6316/C3
if parameter 99.05 Motor ctrl
Hd
manuals search engine
IP 55
IA/IN t E/s
cos
0.83
0.83
0.83
0.83
0.83
0.83
180
IEC 34-1
IP 55
cos M
t
IA/IN
E/s
0.97
630kg
IEC 34-1
... 2 × I
of
Hd
Hd
99.05 Motor ctrl mode
Note: Set the motor data to
exactly the same value as on the
motor nameplate. For example, if
the motor nominal speed is 1470
rpm on the nameplate, setting the
value of parameter 99.09 Mot
nom speed to 1500 rpm results in
incorrect operation of the drive.
If D (delta) data is chosen, then
connect the motor in delta.
If Y (star) data is selected, then
connect the motor in star.
99.06 Mot nom current