• Wash the glass tray and rotating drive mechanism in water with a neutral soap solution. These parts are dishwasher
safe.
• Do not submerse the glass tray in cold water if it is still hot: the sudden drop in temperature can cause the glass tray to
break.
Eliminating malfunctions
Malfunction
The oven will not turn on
The oven will not heat
When the oven is operating, the rotating
glass tray makes strange noises
Normal operation
The microwave oven creates static in television and radio signals.
The oven light is dim.
Steam collects on the door and hot air comes out of the ventila-
tion openings.
The microwave oven was turned on without food inside.
Technical Characteristics
AC power voltage:
Nominal output power in microwave mode:
Operation frequency:
Oven capacity:
Glass tray diameter:
The manufacturer reserves the right to change the characteristics of the device without prior warning.
Service life of the unit not less than 5 years
Guarantee
Details regarding guarantee conditions can be obtained from the dealer from whom the appliance was purchased. The bill
of sale or receipt must be produced when making any claim under the terms of this guarantee.
This product conforms to the EMC-Requirements as laid down by the Council Directive 89/336/EEC and to the
Law Voltage Regulation (73/23 EEC)
1695.indd 7
1695.indd 7
Possible causes
The power plug is not firmly connected to
the electrical outlet
Problem with power outlet
The door is not closed firmly
The roller ring or the cooking chamber
floor is dirty
Static in television and radio signals can occur while the oven
is operating. Similar static is created by small electrical devices
like mixers, vacuum cleaners and electrical fans. This is a normal
occurrence.
If the oven is set to a low power level, the light in the cooking
chamber may also be low. This is a normal occurrence.
During the cooking process, steam is released from the food.
Most of the steam is released through the ventilation openings,
but some can collect on the inside of the door. This is a normal
occurrence.
Turning on the microwave oven for a short period of time while
empty will not cause any harm. Always make sure there is food in
the oven before starting it.
220 V ~ 50 Hz
800 W
2450 МHz
20 Litres
245 mm
7
ENGLISH
Method of elimination
Remove the power plug from the outlet.
Wait 10 seconds and then replace
Try plugging another electrical device into
the outlet to test it
Close the door firmly
Remove the glass tray and roller ring. Wash
the roller ring and the cooking chamber
floor