micro CA-350x Inspection Camera
also be used with other SeeSnake Inspection
Equipment for viewing and recording only.
For use with SeeSnake Inspection Equip -
ment, the imager head and any cable exten-
sions must be removed. For the microReel,
microDrain™, nanoReel and similar equip-
ment, see the operator's manual for informa-
tion on proper connection and use. For other
SeeSnake Inspection Equipment (typically a
reel and monitor), an adapter must be used to
connect the micro CA-350x Inspection Camer a
to a Video-Out port on the SeeSnake Inspec -
tion Equipment. When connected in this man-
ner, the micro CA-350x Inspection Camera
will display the camera view and can be used
for recording.
When connecting to SeeSnake Inspection
Equipment (microReel, microDrain™, or nano -
Reel), align the interconnect module connected
to your reel with the cable connector on the
micro CA-350x Inspection Camera, and slide it
straight in, seating it squarely. (See Figure 18.)
Figure 18 – Camera Connector Plug Installed
Do not twist the connector plug to
NOTI E
prevent damage.
Locating the Sonde
If used with a sonde (In-Line Transmitter), the
sonde can be controlled two ways. If the reel is
equipped with a sonde key, that can be used to
turn the sonde ON and OFF. Otherwise, the
sonde is turned ON by decreasing LED bright-
ness to zero. Once the Sonde has been lo-
cated, the LEDs can be returned to their nor-
mal brightness level to continue the inspection.
A RIDGID locator such as the SR-20, SR-60,
Scout
®
, or NaviTrack
used to locate features in the drain being in-
spected.
14
®
II set to 512 Hz can be
Figure 19 – Locating the Reel Sonde
To locate the Sonde, turn the locator ON and
set it to Sonde mode. Scan in the direction of
the Sonde's probable location until the locator
detects the Sonde. Once you have detected
the Sonde, use the locator indications to zero
in on its location precisely. For detailed in-
structions on Sonde locating, consult the Oper -
ator's Manual for the locator model you are
using.
Maintenance
WARNING
Remove battery before cleaning.
• Always clean the imager head and cable
after use with mild soap or mild detergent.
• Gently clean the display screen with a
clean dry cloth. Avoid rubbing too hard.
• Use only alcohol swabs to clean the cable
connections.
• Wipe the hand held display unit down with
a clean, dry cloth.

Reset Function

If the unit stops functioning and does not op-
erate, press the Reset Button (under the left
side port cover – Figure 4). The unit may re-
cover to normal operation when re started.

Optional Equipment

WARNING
To reduce the risk of serious injury, only
use equipment specifically designed and
recommended for use with the RIDGID
micro CA-350x Inspection Camera such
as those listed below. Other equipment
suitable for use with other tools may be
hazardous when used with the micro
CA-350x Inspection Camera.