REPAIR
For PVC part.
If the spa is torn or punctured, use the
provided underwater adhesive repair
patch.
1. Clean area to be repaired.
2. Carefully peel patch.
3. Press patch over area to be repaired.
4. Wait 30 seconds before inflation.
Make sure the spa and pump are completely dry. This is essential to extend the life of the spa. We recommend using the pump to blow dry the spa, pump
and pipes. Remove the filter sets and discard the used filter cartridges. Re-attach the two stopper caps onto the spa's inlet and outlet valves. It is
recommended you store the spa in its original package in a warm dry place.
NOTE: Plastic becomes brittle and susceptible to breaking when exposed to subzero temperatures. Freezing can severely damage the spa. Improper
winterization of your spa can void your warranty.
Disposal
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local
authority or retailer for recycling advice.
TROUBLESHOOTING
Bestway strives to provide the most trouble-free spas on the market.
If you experience any problems whatsoever, do not hesitate to contact Bestway or your authorized dealer. Here are some helpful tips to help you to
diagnose and rectify some common sources of trouble.
Problems
Pump does not operate
Pump does not
heat properly
Lay-Z-Massage System
does not work
Pump adapters are not
level with the spa
adapters
Spa pool leakage
Water is not clean
PRCD test failed
Control panel not
working
What kind of chemicals
should be used for water
maintenance?
Water leaks from the
adapters between the
pump and spa
For Tritech PVC material.
If the spa is torn or punctured, use the provided PVC repair patch and glue (not included) following these steps:
1. Clean and dry area to be repaired.
2. Cut the provided PVC patch to appropriate size.
3. Use glue (not included) to coat the one side of the newly cut patch. Make sure the glue is evenly distributed.
4. Wait for 30 seconds and then place the cut patch with glue over the damaged area.
5. Smooth out any bubbles of air that may be trapped underneath, and press firmly for two minutes.
6. The product is once again ready for use. Repeat this process should further leaks occur.
7. Wait 30 minutes before inflation.
Probable Causes
- Power failure
- Power circuits broken
- Temperature set too low
- Dirty Filter Cartridge
- The thermal cut-out cut off
- Spa is not covered
- Heating element failed or
fuse cutout
- Air Pump is overheating
- The Lay-Z-Spa Massage
stops automatically
- Air pump is broken
One characteristic of PVC
is that it changes shape,
which is normal
- Spa is torn or punctured
- Air valve is loose
- Insufficient filtering time
- Dirty Filter Cartridge
- Improper water maintenance
Something wrong with
the SPA
The control panel has an auto-lock,
which is activated after 5 minutes of
inactivity. The LED display has one
icon:
If the lock icon is highlighted,
the control panel is locked.
- Control panel is not activated.
Please consult your local chemical supplier for information about chemical maintenance.
Pay close attention to the chemical manufacturer's instructions
Insert the stopper caps on to the spa's ports to prevent water from escaping and disconnect the pump. Check and
make sure the seals are placed correctly inside the pump adapters. If the seals are missing or not installed
correctly, to get assistance visit our website www.bestwaycorp.com support section. If the seals are correctly in
place, reconnect the pump to the spa and hand-tighten the adapters
Solutions
- Check power source
- To get assistance visit our website www.bestwaycorp.com support section
- Set to a higher temperature refer tosection pump operation
- Clean/replace the filter cartridge referto section filter cartridge
cleaning and replacement
- Unplug the pump, and put the plug in a dry, cool place. Only restart the
pump when the water temperature reaches 35°C (95°F) or lower
- Attach the cover
- To get assistance visit our website www.bestwaycorp.com support section
- Unplug the pump and wait two hours until the pump has cooled. Insert
the plug and press the Lay-Z-Massage System Button
- Press the Lay-Z-Massage System Button to reactivate
- To get assistance visit our website www.bestwaycorp.com support section
- Elevate the pump with wood or another type of insulated material to
bring the pump's adapters level with the spa's adapters
- Use provided repair patch
- Using soapy water, cover the air-valve to check if air is leaking, if so,
use the provided wrench to fasten the air-valve following these steps:
1. Deflate the SPA.
2. With one hand, hold the backside of the air valve from the inner side
of the spa wall and turn the wrench clockwise.
- Increase filtration time
- Clean/replace the Filter Cartridge (refer to Filter Cartridge Cleaning and
Replacement section)
- Refer to the chemical manufacturer's instructions
To get assistance visit our website www.bestwaycorp.com support
section
- To unlock the control panel, press the
If the control panel will not unlock, restart the pump – unplug and
plug in the pump
- Press the on/off button for 2 seconds. If the problem persists,
to get assistance visit our website www.bestwaycorp.com support