External power supply

The load cell features a digital output with RS--485 (4--wire) interface. For the power supply an
external DC supply voltage is required.
Power supply unit selection for C16i...:
Procedure for selecting a suitable power supply unit to supply power to the interface converter and
the connected C16i load cells:
1. Determine the required cable length between power supply unit and junction box by examining
the actual on site situation.
2. In the table below, read off actual power consumption values in relation to the number of load cells
used.
3. Select cable cross--section in the relevant line such that the required cable length can be
implemented. With a 15VDC nominal voltage, it is always possible to implement longer cables or
smaller wire cross--sections than with a 12VDC rating.
4. Read off voltage and minimum current for the (plug--in type) power supply unit required. The power
supply unit should be electronically controlled.
Example: 6 load cells require approx. 370mA (this corresponds to the minimum current required
by the power supply unit), the required cable length is to be 100m. At 15VDC, this can be
implemented with a cable cross--section of 0.14mm
2
0.25mm
needs to be selected.
Power supply table (when using the HBM interface converter set SC232/422A with an internal
consumption of approx. 70mA):
Number of
load cells
load cells
1
2
3
4
6
8
10
12
16
* incl. HBM interface converter set SC232/422A
Note:
The plug--in power supply unit , included in the scope of delivery for the HBM interface converter set
SC232/422A supplies 12VDC/700mA. So it can be used for operation with max. 12x C16i load cells.
3.3
Command set C16i...
Please request the separate documentation of our AD104* electronics, if required.
* Operating instructions available in German + English language versions
Downloaded from
www.Manualslib.com
Wägezelle
Sum
Sum
Nominal voltage 12VDC
(
(current con-
sumption) *
ti
) *
Wire cross--section
2
0.14mm
120 mA
352 m
170 mA
176 m
220 mA
117 m
270 mA
88 m
370 mA
59 m
470 mA
44 m
570 mA
35 m
670 mA
29 m
870 mA
22 m
manuals search engine
Load cell
2
. At 12VDC, a minimum cross--section of at least
Maximum cable length
between converter and junction box
2
2
0.25mm
0,5mm
0,14mm
500 m
500 m
500 m
314 m
500 m
296 m
210 m
419 m
197 m
157 m
314 m
148 m
105 m
210 m
100 m
79 m
157 m
63 m
126 m
52 m
105 m
39 m
79 m
MA.C16i.0def -- 284.00--1053.4 -- Version a -- 05.04.2001
Capteur de pesage
C16i...
Nominal voltage 15VDC
Wire cross--section
2
2
0,25mm
0,5mm
500 m
500 m
500 m
500 m
352 m
500 m
264 m
500 m
176 m
352 m
74 m
132 m
264 m
59 m
106 m
211 m
49 m
88 m
176 m
37 m
66 m
132 m