Cause
The measured current is above the limit.
Remedy
Make sure that the Mains Power connection setting in
Grundfos GO Remote is configured correctly according to
input connections.
Make sure that the Mains Power connection setting in
Grundfos GO Remote is configured correctly according to
pump connections.
Make sure that the pump is connected to the correct
contactor terminals (T1, T2, T3) depending on the
configuration in Mains Power connection.
Remove load from non-configured contactor terminals (T2,
T3) depending on the configuration in Mains Power
connection.
8.22 Code 165 (Signal fault)
Alarm code 165 is shown on the display.
The alarm symbol on the display turns red and the pump stops.
Alarm code Signal fault is displayed in Grundfos GO Remote.
Cause
The signal from the sensor is out of the configured range.
Remedy
Go to Settings > Level control in Grundfos GO Remote and
ensure that the configured range corresponds to the physical
application type.
Change the sensor, if needed.
Related information
6.6.1 Setting the after-run delay, high level
8.23 Code 181 (Signal fault, PTC input)
Alarm code 181 is shown on the display.
The alarm symbol on the display turns red and the pump stops.
Alarm code Signal fault, PTC input is displayed in Grundfos
GO Remote.
Cause
There is a signal fault in the PTC input.
Remedy
Make sure that the two PTC wires from the pump are
connected correctly to the terminals on the product.
Make sure that the third PTC wire is left unconnected, if
present.
Make sure that the PTC wires are undamaged.
Make sure that the PTC sensors within the pumps are
undamaged.
Perform a test by disconnecting the PTC wires from the
pump and shorting PTC1 terminal A and B and also PTC2
terminal A and B, and verify that the error is cleared.
Replace the product due to damaged PTC circuit. Contact
Grundfos.
Related information
2.3.3 Connecting the pump supply and power supply
8.24 Code 191 (High water level)
Alarm code 191 is shown on the display.
The alarm symbol on the display turns red, but the pump's
operating mode is unchanged.
Alarm code High water level is displayed in Grundfos GO
Remote.
Cause
The defined start level did not start the pump.
Remedy
Check and configure the sensor start level.
Cause
The pump is not big enough to remove the water.
Remedy
Contact Grundfos or an authorised service workshop.
Cause
The level sensor is defective and not reacting on level changes.
Remedy
Check the functionality of the level sensor.
Related information
3.6 Configuring the IO terminals using Grundfos GO Remote
8.25 Code 205 (Level switch inconsistency)
Alarm code 205 is shown on the display.
The alarm symbol on the display turns red and the pump
stops.
Alarm code Level switch inconsistency is displayed in
Grundfos GO Remote.
Cause
A float switch could be defective or stuck.
Remedy
Check the functionality of each float switch.
Related information
3.6 Configuring the IO terminals using Grundfos GO Remote
6.6.1 Setting the after-run delay, high level
8.26 Code 220 (Contactor wear out)
Warning code 220 is shown on the display if you press
the Up or Down button.
Alarm code 220 is shown on the display.
The alarm symbol on the display turns red and the pump
stops.
The warning symbol on the display turns yellow and the pump's
operating mode is unchanged.
Alarm code or warning code Contactor wear out is displayed
in Grundfos GO Remote.
Cause
The contactor has reached its maximum number of operating cycles
and is worn out.
Alarm: The contactor is worn out and the pump cannot start.
Remedy
Replace LC 231. Contact Grundfos.
Cause
The contactor is approaching its maximum number of operating
cycles and must be replaced.
Warning: The contactor is close to being worn out and the pump will
be unable to start.
Remedy
Order a new LC 231 to avoid downtime. Contact Grundfos.
Related information
6.16.4 Setting the motor protection with Grundfos GO Remote
8.27 Code 229 (Water on floor)
Warning code 229 is shown on the display if you press
the Up or Down button.
The warning symbol on the display turns yellow and the pump's
operating mode is unchanged.
Warning code Water on floor is displayed in Grundfos GO
Remote.
Cause
The sensor detects water on the floor.