Herunterladen Inhalt Inhalt Diese Seite drucken

Relay Digital Outputs (Doxx) - ECOFOREST ecoSMART e-manager Installerhandbuch

Vorschau ausblenden Andere Handbücher für ecoSMART e-manager:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

2.7.

Relay digital outputs (DOxx)

The controller program allows managing up to four non-critical loads when we have electrical surplus. The four relays that enable
these loads are included in the box of the ecoSMART e-manager. The supply of each relay is independent, so that different working
voltages can be used in each of them. The following figure shows an example of the installation of the power supply of a relay.
POWER
SUPPLY
8
7
6
24 Vac
FBus
BMS2
Figure 2.8. Example of power supply connection to relays of the digital outputs
Each relay allows cutting the poles (line + neutral) with a capacity of 8A / 250Vac per pole. If the equipment to be controlled
exceeds this capacity it is necessary to install an external relay.
Pay particular attention to the maximum consumption allowed by the relays. If necessary use an intermediate relay to make the
connection.
NOTE
CHiNT
NH4-2-32
J16
J17
J18
J10 FBUS1
J11 BMS2
J14 pLAN
J27
J15
pCOOEM+
J25
5
J1
J2
J3
J4
pLAN
Installer manual ecoSMART e-manager
NC
COM
NO
COIL
J19
J20
J21
J22
J23
J24
J28
J29
J26
J5
J6
J7
DI1
DI2
DI3
DI4
DI5
DI6
35
L N
PE
NC : 22/12
COM : 21/11
NO : 24 / 14
NC
COM
NO
A2 A1
/

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis