Energy manager power supply

The ecoSMART e-manager power supply requires a single phase power supply L/ N / PE, 230 V / 50 Hz. The recommended section
of the wires for the power supply is 1.5 mm2.
For the electrical installation, bring the power cable to the upper left of the box and route it to the power terminal block as shown
below.
POWER SUPPLY
The e-manager controller is powered by an alternating current at 24V. The electrical box includes a transformer and the
overcurrent protections needed to protect your equipment.
If you are forced to replace any of the protection fuses present in the box, do it with a fuse of the same maximum current value.
NH4-2-32
POWER
SUPPLY
8
7
6
24 Vac
FBus
BMS2
Figure 2.4. ecoSMART e-manager power supply scheme.
31