Operating the field indicator

5.2

Electrical connection

Both the terminal assignment and the connection values of the field indicator correspond to
those of the Ex-version. The device is only designed for operation in a 4 to 20 mA measuring
circuit. There must be potential equalisation along the circuits (within and outside the
hazardous area).
5.3

Degree of protection

The devices fulfill all the requirements for IP 67 degree of protection. Compliance with the
following points is mandatory following installation or servicing in order to ensure that IP 67
protection is maintained:
• The housing seal must be clean and undamaged when inserted into the seal groove. The
seal may have to be cleaned, dried or replaced.
• The cables used for connection must be of the correct specified outside diameter (e.g. M20 x
1.5, Kabeldurchmesser 8 to 12 mm (0.3 to 0.47 in)). Install the device upright in such a way
that the cable entries point downwards.
• Replace any unused cable entries with dummy plugs.
• The grommet used should not be removed from the cable entry.
• The housing cover and the cable entry must be well tightened.
5.4

Post-connection check

Perform the following checks after completing electrical installation of the device:
Device condition and specification
Are the device or the cables damaged?
Electrical connection
Is the cable type route completely isolated - without loops and cross-overs?
Are the cables strain relieved?
Is the terminal assignment correct? Compare with the connection diagram of the terminal block
Are all terminal screws tightened?
Is the cable gland sealed?
Is the housing cover tightened?
6
Operating the field indicator
6.1

Display and operating elements

Display
30
Downloaded from
www.Manualslib.com
manuals search engine
Note
Visual inspection
Note
-
-
→  29
Visual inspection
Visual inspection
Visual inspection