Herunterladen Inhalt Inhalt Diese Seite drucken

Massoth eMOTION Konfigurationsanleitung Seite 27

Vorschau ausblenden Andere Handbücher für eMOTION:
Inhaltsverzeichnis

Werbung

Table of configuration variables
CV Description
1
Loco Address (Standard Short)
2
Starting Voltage
3
Acceleration Time
4
Braking Time
5
Top Speed
6
Mid Speed
5+6 Programming in Register Mode:
Register 6 = CV No.
Register 5 = Value
7
Software Version
7
Decoder Reset Functions
(3 Ranges Available)
(see also Attachment 10)
8
Manufacturer ID
9
Motor frequency
13 Function Outputs in Analog Mode
(On if Value Set)
17 Long Loco Address (High Byte)
18 Long Loco Adress (Low Byte)
19 Consist adress
29 Configuration Table NMRA
49 Configuration Table MASSOTH
50 Light: Dimming Value (PWM)
Downloaded from
www.Manualslib.com
manuals search engine
D
A
Range Note:
3
1... 127 If CV 29 bit 5 = 0
2
1... 255 CV 2 x (1/255 track voltage)
3
1... 255 CV 3 x 2ms x (1/255 track v.)
3
1... 255 CV 4 x 2ms x (1/255 track v.)
255
1... 255 CV 5 x (1/255 track voltage)
64
1... 255 CV 6 x (1/255 track voltage)
---
---
CV 5 and CV 6 are not effected
---
---
read only
55
basic setting
66
reset motor setting
77
reset lights and functions
123
---
read only
0
0... 3 0 = 16 kHz
1 = 2 kHz
2 = 250 Hz
3 = 60 Hz
3
0... 63 A1 = 1 Add the values to the
A2 = 2 desired functions!
A3 = 4
A4 = 8
A5 = 16
A6 = 32
128...
Only active
128
10239
if CV29 bit 5 = 1
0
0... 99 Autom. consist address Lenz
4
see Attachment 1
2
see Attachment 2
32
1... 32 32 = full track voltage
®
27

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis