Downloaded from
www.Manualslib.com
- Switch off system power.
- Wait for the warning lights on the control
Low mains
panel to go off, then power the system
voltage (LP)
again.
- Check that the mains voltage is correct,
if necessary reset it at the plate values.
- Switch off system power.
- Wait for the warning lights on the control
High mains
panel to go off, then power the system
voltage (HP)
again.
- Check that the mains voltage is correct,
if necessary reset it at the plate values.
- Switch off system power.
- Wait for the warning lights on the control
Critical over-
panel to go off.
heating of
- Check that the system ventilation ducts
are not blocked and that the environ-
ment temperature of the premises is
correct.
- Check that the circulator turns freely.
Protection
- Check that any antifreeze added does
against
not exceed the maximum percentage
overcurrent
of 30%.
- Switch off system power.
- Wait for the warning lights on the control
panel to go off, then power the system
Voltage Error
again.
- Check that the mains voltage is correct,
if necessary reset it at the plate values.
Twin
- Check that the twin communication ca-
ble is intact.
absent
- Check that both circulators are pow-
ered.
Dry operation
- Put the system under pressure.
- Switch off system power.
Motor excess
- Wait for the motor to cool down
temperature
- Power the system again
manuals search engine
f < 100 Hz
 
e57 ; e58
f > 5 kHz
Energy Efficiency Index - EEI
EVOPLUS 40/180 M
EVOPLUS 60/180 M
EVOPLUS 80/180 M
EVOPLUS 110/180 M
EVOPLUS 40/180 XM
EVOPLUS 60/180 XM
EVOPLUS 80/180 XM
EVOPLUS 110/180 XM
EVOPLUS B 40/220.32 M
EVOPLUS B 60/220.32 M
EVOPLUS B 80/220.32 M
EVOPLUS B 110/220.32 M
EVOPLUS B 40/250.40 M
EVOPLUS B 60/250.40 M
EVOPLUS B 80/250.40 M
EVOPLUS B 110/250.40 M
EVOPLUS D 40/220.32 M
EVOPLUS D 60/220.32 M
EVOPLUS D 80/220.32 M
EVOPLUS D 110/220.32 M
EVOPLUS D 40/250.40 M
EVOPLUS D 60/250.40 M
EVOPLUS D 80/250.40 M
EVOPLUS D 110/250.40 M
The benchmark for the most efficient circulators is EEI ≤ 0,20.
ENGLISH
Check that the PWM external signal is
operating and connected as specified.
0,23
0,22
0,22
0,22
0,21
0,21
0,21
0,21
0,22
0,22
0,22
0,22
0,21
0,21
0,21
0,21
0,23
0,23
0,23
0,23
0,22
0,22
0,22
0,22