10. Commissioning and System Test

When the alarm system is properly installed and all connection work has been com-
pleted successfully, commissioning can be continued. For this purpose, proceed as
follows:
• Activate the power source to supply the alarm system with operating voltage.
• After switching on operating voltage, a short signal sound is issued. The alarm
system now requires approx. 90 seconds for initialisation. During this initialisa-
tion, the status LED "EXIT" flashes quickly. After the end of the initialisation
stage, the status LED "EXIT" goes out.
• Set the "mode selection switch" to "AWAY" (since this switch position arms both
alarm zones).
The exit delay (approx. 60 seconds) commences now. During the exit delay, the
status LED "EXIT" flashes quickly. After the end of the exit delay, a short signal
sounds and then the status LED "EXIT" flashes slowly.
• The alarm system is now armed.
• Activate a sensor in alarm zone 2. The exit delay (approx. 30 seconds) com-
mences now. If the signal sounds are activated, they are issued. The status LED
"EXIT" also flashes slowly. After the end of the entry delay, the alarm is triggered
and the status LED "EXIT" is permanently lit.
Downloaded from
www.Manualslib.com
The status LED "EXIT" is lit permanently when a sensor has triggered
in the alarm zone (this applies if the mode selection switch is set to
"HOME" or "AWAY"). In this case, check correct connection of the sen-
sors and whether or not the sensor is activated. Verify, e.g., whether
windows and doors are closed and thus the door/window detectors con-
nected to them are not activated.