Herunterladen Inhalt Inhalt Diese Seite drucken

Conrad 75 21 68 Bedienungsanleitung Seite 29

2-zonen alarmanlage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Alarm zone 1 triggers the alarm
immediately in case of alarm.
Alarm zone 2 triggers the alarm
with a delay after the end of the entry
delay (= 30 seconds).
Alarm zone 1 corresponds to terminal clamps 1 and 2.
Alarm zone 2 corresponds to terminal clamps 2 and 3.
Terminal clamp 2 is the joint reference point (-) for both alarm zones.
Connect the sensors with N.C. contacts in sequence, and those with N.O. contacts
in parallel.
If no sensors with N.C contacts are used, a 10kOhm EOL resistor must be integrat-
ed to secure the switching circuit (included in the delivery).
Downloaded from
www.Manualslib.com
Alarm zone 2 is best suitable for sensors that are installed in the inside
area (such as motion detectors), since these sensors would trigger
alarm when the house is entered. An alarm is only triggered after the
end of the activation delay (= 30 seconds). The alarm system can be
disarmed in this period (for this, the mode selection switch at the front
must be returned to the "OFF" position).
To ensure proper sensor operation with an N.C. contact it must be
ensured that every sensor with an N.C.contact has a maximum resis-
tance of 1kOhm.
manuals search engine
Connection example alarm zone 1:
Connection example alarm zone 2:
29

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis