8. Mode Selector Switch Functions
Use the mode selection switch to determine the three different operating modes.
OFF
HOME
AWAY
OFF
HOME
AWAY
OFF
HOME
AWAY
During the exit delay, the status LED "EXIT" flashes quickly. After the end of the exit
delay, there is a short signal sound (depending on the position of jumper B). When
the alarm system is armed, the status LED "EXIT" flashes slowly.
9. Jumper Functions
Jumper 1 (internal signalling device)
1 2
A
1 2
A
Downloaded from
www.Manualslib.com
The mode selection switch is at the front of the alarm system.
OFF:
The complete alarm system is switched off. The door bell
function is exempted from this.
HOME: The alarm system is switched on and the exit delay starts
(duration = 60 seconds). After the end of the exit delay, only
alarm zone 1 is armed.
AWAY: The alarm system is switched on and the exit delay starts
(duration = 60 seconds). After the end of the exit delay, both
alarm zones are armed.
The jumpers are on the PCB to the right of the connection terminal.
ACTIVATED
In case of an alarm, an acoustic alarm is triggered
by the internal signalling device.
DEACTIVATED In case of an alarm, no acoustic alarm is triggered
by the internal signalling device. This does not app-
ly to the internal door bell and the signal sounds.
manuals search engine