Herunterladen Inhalt Inhalt Diese Seite drucken

Tecsis P3230 Betriebsanleitung Seite 21

Pegelsonde
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7. Starting, operation
Speciications
Pressure ranges
»
P3230 / {P3233 with FEP cable}
Over pressure safety
Burst pressure
Pressure ranges
»
P3233 with PUR cable
Over pressure safety
Burst pressure
Materials
Wetted parts
Pressureconnection/diaphragm
Protection cap
Cable
Power supply U
B
Signal output
Betriebsanleitung/Operating instructions
Model P3230 / P3233
bar
1)
0.25 0.4
bar
2
2
1)
bar
2.4
2.4
1)
bar
1)
0.1
0.16 0.25 0.4
bar
1
1.5
1)
bar
1)
2
2
1 bar = 10.2 mH
O
1)
2
Model P3230
Stainless steel
Stainless steel
PA
PUR
≤ 30
U
in VDC
10 < U
B
B
4 ... 20 mA, 2-wire
For pressure ranges ≥ 0 ... 0.25 bar.
2)
0.6
1
1.6
2.5
4
4
5
10
10
10
4.8
6
12
12
12
0.6
1 1.6 2.5
2
2
4
5 10 10
2.4
2.4
4.8
6 12 12
Model P3233
Stainless steel {Hastelloy}
Stainless steel {Hastelloy}
PA {stainless steel} {Hastelloy}
PUR {FEP}
10 < U
(14 ... 30 with signal
output 0 ... 10 V)
(5 ... 30 with battery operation,
signal output 0.5 ... 4.5 V)
4 ... 20 mA, 2-wire
0 ... 20 mA, 3-wire
{0 ... 5 V, 3-wire}
{0 ... 10 V, 3-wire}
{0.5 ... 4.5 V, 3-wire, with battery
operation}
{Pt100, 4-wire; IEC 60751}
GB
6
10
10
10
12
12
4
6
10
16
25
17
35
35
35
35
20.5 42
42
42
42
≤ 30
B
2)
21

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

P3233

Inhaltsverzeichnis