BTL7-S510(B)-... / BTL7-S5 _ _ C-... / BTL7-S5 _ _ D-...
BTL7 Configuration Tool
3
Windows and tabs (continued)
3.3
Magnet tab
3.3.1

Number of magnets

► Select the number of magnets used.
U
does not need to be clicked on, clicking a radio
pdate btl
button immediately updates the BTL and the graphic.
For the "2 magnets" setting there must be
exactly two magnets on the BTL.
3.3.2
Assignment
Graphical display of the magnets and their output
functions.
Boundary conditions for several magnets
Two magnets can only be selected if the nominal length
is ≥ 90 mm.
The distance between two magnets must be ≥ 65 mm.
www.balluff.com
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is part
of a closed loop system whose parameters have not yet
been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► The system must be taken out of operation before
configuration.
► BTLs may only be connected to the communication
box for configuration.
► The communication box must be removed after
configuration.