6 ALARM MANAGEMENT

If a malfunction occurs, the following procedure is activated:
1) audible alarm (beep);
2) one of the following system LEDs come on:
3) if the problem concerns an error, the stove will switch off.
Pressing and holding the "cancel" button
ERROR/
WARNING CODE
E001
E002
E004
E101
E105
E106
E108
*
E109
E110
E111
A001
A002
A007
----
----
* Only for the models equipped with safety microswitches on the door or on the hopper lid.
After having checked the type of message, the alarm can be reset by pressing the on/off button
moments.
If the error code is "
stove (Fig. 6.1) ( this should be carried out by an authorized technician).
Before proceeding with a new ignition, check that:
the stove has cooled
the burning pot is clean and free of any ash residue or pellet
the burning pot is correctly positioned in its seat
the doors of the hearth and the tank are perfectly closed
26
DESCRIPTION
Faulty control panel
Remote control signal communication error
Communication error
Failed ignition error
Pellet probe malfunction
Temperature probe malfunction
Safety error
Pressure error or thermal safety
Temperature probe malfunction
Flue gas temperature probe malfunction
Low pellet level (icon flashing)
Scheduled maintenance warning (icons flashing) The stove periodically requires maintenance to be
Pressure sensor malfunction (icon flashing)
Clean stove
Failed ignition error
E109
", before resetting the alarm, manually reset the thermostat located on the rear of the
;
shows the error code on the display:
Control panel fault
Control panel fault
Connection cable between board and control panel
interrupted or detached.
If this appears when changing configuration, ignore
the error
No pellets
Pellet quality
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
Pellet probe disconnected or faulty
Faulty air temperature probe
Door or hopper lid open
Flue gas exhaust system dirty
Seal gaskets worn
Insufficient combustion air
Problems with overheating in the pellet hopper
Faulty air temperature probe
Faulty flue gas temperature probe
Pellets running out
performed by a qualified technician
Pressure sensor or board fault.
Combustion chamber, burn pot or flue gas exhaust
system dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
No pellets; Faulty ignition heater; Worn gaskets;
Incorrect burn pot position
POSSIBLE CAUSES
LED
for a few
fig. 6.1