4 STOVE OPERATION

4.1 STARTING THE STOVE
Before every ignition, be sure that burning pot is completely empty and properly positioned in its seat.
To start the stove hold the
The flame icon will start flashing during the ignition stage until remaining on steady when the stove has started.
Automatic stove ignition: the stove comes with an automatic device that starts the pellet stove without using other
traditional fire lighters.
Avoid lighting the flame manually if the stove's automatic ignition system is not working correctly.
When the stove is started the first time, unpleasant odours or smoke may be generated, caused by evaporation
or drying of certain materials used. This phenomenon will gradually disappear.
The room should be well ventilated when starting the stove the first few times.
"Sealed" series stoves
When opening the firebox door, never leave it open too long, otherwise the door sensor will set off the
open door signal (audible alarm).
4.2 MODIFYING THE PARAMETERS
The stove operating parameters can be modified as described.
The values set will be retained until next modified, even when the stove is switched off or unplugged from the
power supply.
4.3 SWITCHING OFF
To switch the stove off hold the
To start the stove again it's recommended to wait for the stove to cool down completely.
The stove should only be switched off following the procedure described above. Never switch the stove off by
unplugging it from the power supply.
4.4 OPERATION WITH ROOM THERMOSTAT
When the stove is controlled by an external thermostat (or timer thermostat) the installer must have set
Configuration 2. In this configuration the stove switches off when reaching the external thermostat setting.
The stove switches on again automatically when the temperature falls below the value set on the external
thermostat (circuit closed).
On first ignition, or if the stove has been switched off manually (
directly from the control panel.
4.5 OPERATION WITH ROOM PROBE ON THE STOVE
The stove can be switched on/off manually or in programmed mode.
The stove modulates output according to the room temperature read by the probe on the stove (that is, the stove
attempts to maintain the desired temperature while minimising fuel consumption).
If the user has enabled the "Eco-mode" function , the stove rather than modulating its output, switches
off when reaching the set temperature, and switches on again when the room temperature falls below
the delta set.
The desired room temperature can be set in the temperature menu
button for several seconds.
button for a few seconds; the flame icon will switch off.
button), the stove needs to be started
.