Reset DMX values of a step:
To reset the DMX values of a step proceed as follows:
Press key MENU one time. Then press 5 times key +
STANDALONE STEPS will be shown on the display
Confirm by pressing key ENTER.
STEP NR. 1/X will be displayed. Recall the desired step by means of the keys + and - and
confirm the selection by pressing key ENTER.
Select function RESET STEP by means of the keys + and -
After selecting the function press key ENTER.
SURE? will be displayed. Confirm selection by pressing key ENTER again.
The DMX values of the selected step will be set to "0"
Store cues from a DMX board:
Select the Standalone menu.:
Press key MENU first and then press key + five times.
STANDALONE STEPS will be displayed. Confirm selection by pressing key ENTER.
Then press key + one time to enter capture function.
CAPT DMX 1/ 1 will be displayed. Press ENTER to enable the fixture to receive DMX data
from a connected DMX board. To store data press ENTER again.
The display will show: CAPT DMX 1/1
To insert a new step press key +
The display will show: SURE?
Press ENTER to confirm and the display will show:INSERT 2/2
To continue programming press key - one time and find: CAPT DMX 2/2
shown on the display.
Press ENTER to enable fixture to receive DMX data, and see confirmation DMX CAPTURE
on the display.
Repeat the process of storing data on the fixture by pressing ENTER again.
(Press enter first time: START CAPTURE;
Press enter second time: CAPT DMX X / X)
To continue, insert a new step and repeat process.
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein Telefon +49 (0)7304-9617-0