2. Installation

2.1 Installing or changing the lamp
WARNING: Disconnect fixture from mains, and allow
hot lamp to cool down for at least 30 minutes!
Light source: OSRAM HMI 1200W/S
Position head in horizontal position. Hinge no. 1 must be on the
upper side of the head. Turn screws no. 5 1/2 turn left and remove
plastic lid.
Loosen knurled head screw no. 3 and open the lampcover
With the nipple of the lamp facing the back insert one end of the
lamp into the socket. Pull up the spring of the other side of the
.
socket and snap the other end of the lamp into place.
Remove the knurl nut on both ends of the lamp.
The knurl nuts are not required with this kind of lampholder.
There is a small milled recess on each end of the lamp. Make sure
it fits correctly into the socket.
If changing the lamp, remove old lamp from
lamp socket. Hold the new lamp only by its
ceramic base. Never touch the glass bulb.
Insert the new lamp in the lamp socket.

2.2 Powering the fixture

WARNING: To ensure propper installation of the plug consult a qualified
technician!
Install a 3-prong gounding type plug that fits your supply
Connected load: voltage 230V, frequency 50Hz, Power 340 VA
brown
blue
yellow/green gound
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein Telefon +49 (0)7304-9617-0
live
"L"
neutral
"N"
milled recess
2
1
3
21