Technical Specifications

POWERTEC 250C-I & 300C-I
Input Voltage
400V ± 10%
Three Phase
Duty Cycle
(
Based on a 10 min. period
250C-I:
35%
60%
100%
300C-I:
35%
60%
100%
Welding Current Range
250C-I:
300C-I:
Fuse or Circuit Breaker Size
250C-I:
300C-I:
Height
815 mm
Operating Temperature
-10°C to +40°C
Input Power at Rated Output
250C-I: 10.8 kVA @ 35% Duty Cycle
300C-I: 14.4 kVA @ 35% Duty Cycle
RATED OUTPUT AT 40°C
)
OUTPUT RANGE
25A - 250A
30A - 300A
RECOMMENDED INPUT CABLE AND FUSE SIZES
16A Superlag
25A Superlag
PHYSICAL DIMENSIONS
Width
460 mm
INPUT
Output Current
250A
190A
145A
300A
225A
175A
Maximum Open Circuit Voltage
250C-I:
300C-I:
250C-I:
300C-I:
Length
925 mm
A-6
Frequency
50 Hertz (Hz)
Output Voltage
26.5 Vdc
23.5 Vdc
21.2 Vdc
29.0 Vdc
25.2 Vdc
22.7 Vdc
41 Vdc
43 Vdc
Input Power Cable
4 Conductor, 2.5mm
4 Conductor, 2.5mm
Weight
250C-I:
300C-I:
Storage Temperature
-25°C to +55°C
2
2
94 Kg
96 Kg