PRODUCT MAINTENANCE
 Mount the filter bowl.
 Slightly tighten the filter bowl using a wrench.
 Mount the tube back on the quick coupling.
Fig. 14: Replacement of filter element
17.9. Check of fan and cooler
The equipment, in particular the compressor fan, cooler fan (21), and the cooler (14), must be kept
clean to ensure efficient drying. Remove dust from surface of the fan or cooling fins by vacuuming
or blowing down with compressed air. (Fig. 2)
17.10. Procedure for connecting a compressor disconnected from the cabinet
Prior to any maintenance or repair work, switch off the compressor and
disconnect it from the mains (pull out the mains plug).
The compressor (without cabinet) requires that the jumper is always mounted in the terminal strip
for correct operation (Fig. 15, Pos. B). It then replaces the switch on the cabinet.
If there is no jumper in the terminal strip of the compressor (disconnected from
the cabinet), the compressor will not work!
If the cord between the compressor and the cabinet becomes disconnected (by pulling the mains
plug) and the compressor is removed from the cabinet, the compressor will not be functional.
Therefore, it is necessary to first create a connection to the terminal strip with a jumper (replacing
the circuit breaker function) (Fig. 15).
PROCES:
Jumper installation (A-B process):
 Disconnect the product from the mains by pulling the plug out of the socket.
 Remove the cover on the electrical panel (on the compressor).
 The jumper is not in the terminal strip – A.
 Insert the jumper into the terminal strip – B.
 Reinstall the cover on the electrical panel.