Working pressure 6 – 8 bar
Nominal voltage
a)
Frequency
Capacity at 5 bar
(FAD)
b)
Working pressure
Max. current
Motor power
Air tank volume
Air quality – filtration
Maximum operating
pressure of safety
valve
Noise level at 5 bar
(L
)
pA
Operating mode
PDP drying at 7 bar
Time to fill air tank
from 0 to 6 bar
Dimensions (net)
w x d x h
Net weight
a)
State the compressor variant in the order
b)
For other range of pressure consult with the supplier
c)
Weight value is only informative data and applies only to a product without any accessories
Dependence of compressor capacity on working pressure
NP-DK50-10-A-4_10-2019-MD
DK50-10Z
V,
230,
115,
Hz
50/60
60
l/min
70/80
80
6.0 – 8.0
bar
A
3.9/4.9
9.0
kW
0.55
l
10
m
-
bar
12.0
≤64/≤66
≤66
dB
%
S1-100
°C
-
s
60/51
51
mm
485x350x553
c)
kg
38
16
DK50-10S
DK50-10Z/M
230,
115,
230,
50/60
60
50/60
70/80
80
60/70
6.0 – 8.0
6.0 – 8.0
3.9/4.9
9.0
4.1/5.1
0.55
10
-
12.0
≤46/≤49
≤49
≤65/≤67
S1-100
S1-100
-
60/51
51
72/61
580x440x655
544x350x553
c)
53
TECHNICAL DATA
DK50-10S/M
115,
230,
60
50/60
70
60/70
6.0 – 8.0
9.2
4.1/5.1
0.55
0.55
10
10
0.3
0.3
12.0
12.0
≤67
≤49/≤52
S1-100
 +3
 +3
61
72/61
649x440x655
44
61
10/2019
115,
60
70
9.2
≤52
61