Dangers Due To Non-Compliance; Water Pressure; Electrical Devices/Equipment - Conel CLEAR 2.0 RD Montage- Und Betriebsanleitung

Hauswasserstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.3

DANGERS DUE TO NON-COMPLIANCE

In detail, failure to observe the general danger symbols can result, for example, in the following risks:
/
Failure of important functions of the domestic water station
/
Danger to persons due to electrical and mechanical effects
/
Danger to persons and the environment due to leaks
Refrain from any unsafe working methods.
Failure to comply with these operating instructions and the safety information can not only result in dan-
gers for persons but can also harm the environment and the unit.
4.4

WATER PRESSURE

The water pressure must not exceed 16 bar inlet pressure. In case of a mains pressure
A
above 16 bar (even temporarily) the domestic water station must not be installed!
Quantity
Nominal pressure
Operating pressure
Discharge pressure
Starting at an operating pressure of 10 bar, increased wear can be expected!
4.5

ELECTRICAL DEVICES/EQUIPMENT

There must not be any electrical cables and devices underneath or in the immedi-
ate vicinity of the domestic water station!
Electrical devices/equipment that are not splash-water proof and are situated in the direct vicinity of the
domestic water station may be damaged by water leaking from the domestic water station during back-
washing or caused as a result of the device not being operated in accordance with the manufacturer's spec-
ifications.
Value
PN 16
1.5 bar - 16 bar (150 - 1600 kPa)
1.5 bar - 6 bar (150 - 600 kPa)
Factory setting: 4 bar (400 kPa)