Default charging parameters in LI mode are programmed for 12.8V LFP battery. Before
using Rover PG to charge other lithium battery, set the charging parameters according to
the suggestions from battery manufacturer.
The above parameters are based on 12V system settings. Parameters are multiplied by 2
2.
for 24V systems, multiplied by 3 for 36V systems, and multiplied by 4 for 48V systems.
For Equalization Interval setting under USER mode, 0 Day refers to close equalization function.
3.
When selecting User, the battery type is to be self-customized, and in this case, the default
system voltage parameters are consistent with those of the sealed lead-acid battery. When
modifying battery charging and discharging parameters, the following rule must be followed:
Over-voltage cut-off voltage > Charging limit voltage ≥ Equalizing voltage ≥ Boost voltage
≥ Floating charging voltage > Boost recovery voltage;
Over-voltage cut-off voltage > Over-voltage cut-off recovery voltage;
Low-voltage cut-off recovery voltage > Low-voltage cut-off voltage ≥ Discharging limit voltage;
Under-voltage warning recovery voltage > Under-voltage warning voltage ≥ Discharging limit voltage;
Boost recovery voltage > Low-voltage cut-off recovery voltage
PV Power – Conversion Efficiency Curves
1.12 Volt System Conversion Efficiency
3. 48 Volt System Conversion Efficiency
33
2. 24 Volt System Conversion Efficiency
Illumination Intensity: 1000W/ m
Temp 25℃
2