Herunterladen Inhalt Inhalt Diese Seite drucken

Fusing; Technical Specifications; Electrical Parameters - Renogy ROVER Serie Installation

Solarregler mit mppt-technologie
Vorschau ausblenden Andere Handbücher für ROVER Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fusing is a recommended in PV systems to provide a safety measure for connections going from
panel to controller and controller to battery. Remember to always use the recommended wire
gauge size based on the PV system and the controller.
AWG
Max.
Current
The NEC code requires the overcurrent protection shall not exceed 15A for
NOTE
14AWG, 20A for 12 AWG, and 30A for 10AWG copper wire.
Controller to Battery Fuse = Current Rating of Charge Controller
Different safety factors could be used. The purpose is to oversize.
NOTE
Total Amperage= Isc1 = Isc2 * SF
= 5.75A * 1.56 = 8.97
Fuse = 9A fuse

Electrical Parameters

Model
Nominal system voltage
Rated Battery Current
Rated Load Current
Max. capacitive load capacity
Battery Voltage
Max Solar Input Voltage
Max. power point voltage range
Max. Solar Input Power
Self-Consumption
Conversion efficiency
MPPT tracking efficiency
Temp. Compensation
31
NEC Maximum Current for different Copper Wire Sizes
16
14
18A
25A
Fuse from Controller to Battery
Ex. 20A MPPT CC = 20A fuse from Controller to Battery
Fuse from Solar Panel(s) to Controller
Ex. 200W; 2 X 100 W panels
**Utilize 1.56 Sizing Factor (SF)
Series:

Technical Specifications

Fusing

12
10
8
30A
40A
55A
75A 95A
Total Amperage= (Isc1 + Isc2) * SF
=(5.75A + 5.75A)* 1.56 = 17.94
12V/24V/36V/48V Auto Recognition
150 VDC (25°C), 145VDC (-25°C)
Battery voltage +2V to 120V
800W/12V; 1600W/24V; 2400W/36V; 3200W/48V
-3mV/°C/2V (default)
6
4
2
130A 170A
Parallel
Fuse = 18A fuse
RVRPG-60
60A
20A
10000µF
9V - 70V
0.7W - 1.2W
≤ 98%
> 99%
0
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rover pg serieRvrpg-60

Inhaltsverzeichnis