Rover PG Protections

Protection
Behavior
When PV shot circuit occurs, the controller will stop charging.
PV Array Short Circuit
Clear it to resume normal operation.
If the PV voltage is larger than maximum input open voltage
150VDC, PV will remain disconnected until the voltage drops
PV Overvoltage
below 150VDC.
The controller will limit the battery charging current to the
maximum battery current rating. Therefore, an over-sized solar
PV Overcurrent
array will not operate at peak power.
If the current exceeds the maximum load current rating 1.05
times, the controller will disconnect the load. Overloading must
Load Overload
be cleared up by reducing the load and restarting the controller.
Fully protected against the load wiring short-circuit. Once the
load short (more than quadruple rate current), the load short
Load Short Circuit
protection will start automatically. After 5 automatic load
reconnect attempts, the faults must be cleared by restarting the
controller.
The controller will not operate if the PV wires are switched. Wire
PV Reverse Polarity
them correctly to resume normal controller operation.
The controller will not operate if the battery wires are switched. Wire
Battery Reverse Polarity
them correctly to resume normal controller operation.
If the temperature of the controller heat sink exceeds 65℃, the
controller will automatically start the reducing the charging
Over-Temperature
current and shut down when temperature exceeds 80℃.