Testing the residual current device
1. Connect the RCD adapter
site.
2. Press the RESET button 12.
The LED
lights up. The heat pump is supplied with electricity and is in the Standby mode.
11
3. Press the TEST button 13.
The LED
lights up. The heat pump is disconnected from the electricity and the Display
11
goes out.
4. Press the RESET button 12.
The LED
lights up. The heat pump is supplied with electricity and is in the Standby mode.
11
The residual current device of the RCD adapter has now been tested successfully.

Activating the heating

In the Operate mode, the temperature can be set between 15 and 35 °C. The initial value set for
the water temperature is 27 °C.
Activating the Operate mode
1. Press the RESET button 12.
The LED
lights up. The heat pump is supplied with electricity and is in the Standby mode.
11
2. Press the On/Off button 15.
The heat pump
1
temperature in °C.
Setting the desired water temperature
1. Press the Up
16
The display
shows the desired water temperature in °C.
14
The heat pump will not run if the desired set water temperature is below the current,
measured water temperature.

Displaying or setting parameters

The heat pump has 11 parameters which can be shown or set via the display
"Parameters").
Displaying the parameters
1. Press and hold the SET button
The display
shows "A".
14
2. Press the Up
16
The display
shows the selected parameter (A, B, C, 1-8; see "Parameters").
14
3. Press the SET button
The value of the selected parameter blinks on the display
Setting the parameters
1. Press the Up
16
The desired value of the selected parameter blinks on the display
2. Press the SET button 18.
The desired value of the selected parameter is now set.
40
C
to the electrical supply that has been prepared at the installation
is in the Operate mode and the display
or Down
17
button repeatedly.
18
for 5 seconds while the heat pump is in the Operate mode.
or Down
17
button repeatedly.
18
to select the required parameter.
or Down
17
button repeatedly.
shows the current water
14
.
14
.
14
14
D
(see