Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions And Information - Hauff-Technik ESH PolySafe Montageanleitung

Vorschau ausblenden Andere Handbücher für ESH PolySafe:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ESH PolySafe - single-line building entry for
buildings with a basement.

Safety instructions and information

Target group
The installation may only be carried out by technical experts.
Qualified and trained individuals carrying out installation must have
• knowledge of general safety and accident prevention regulations as amended,
• knowledge of how to use safety equipment,
• knowledge of how to use hand tools and electric tools,
• knowledge of the relevant standards and guidelines for laying pipes/cables and
for backfilling utility trenches as amended,
• knowledge of the regulations and installation guidelines of the supply company
as amended,
• knowledge of the waterproof concrete directive and building waterproofing
standards as amended.
General information and intended use
In line with their intended use, our products have been developed solely for instal-
lation in buildings made of state-of-the-art materials. Insofar as no express written
confirmation has been provided by us, we do not accept any liability for any other
purposes or purposes going beyond the above.
For warranty conditions, please see our current General Terms and Delivery Conditions.
ESH PolySafe single-line building entry systems meet the requirements of Annex B1
of Test Specification VP 601 dated January 2008 and are compatible with gas building
entries which likewise comply with Supplement B1 in terms of design and construction.
Gas and watertight ESH PolySafe single-line building entry for gas, water,
power and telecommunications services for installation in core drills or wall sleeves.
Basic variant 1 with internal sealing of 30 mm sealing width for buildings with a
basement. Modules enable the external sealing to be freely selected as a function
of the wall type or building sealing, and the standard external sealing (module 1) is
suitable for waterproof concrete.
For further wall types and depending on the building sealing, appropriate modules
from the system must be installed.
ESH PolySafe is suitable for application areas such as standing seepage water, pressu-
rised water, Class 1 waterproof concrete, DIN 18533 W2.1-E and DIN 18533 W2.2-E.
Safety
This section provides an overview of all the main safety aspects for optimum protection
of personnel and a safe installation process.
A failure to observe the instructions and safety information set out here may result
in significant hazards.
When installing the ESH PolySafe single-line building entry, it is imperative to
observe the relevant professional association rules, the VDE provisions, the relevant
national safety and accident prevention regulations and your company's guidelines
(work and procedure instructions).
The fitter must wear the relevant protective clothing.
Only intact components may be installed.
The following instructions are to be observed prior to installa-
tion of the ESH PolySafe
single-line building entry:
WARNING!
Risk of injury in the event of improper installation!
Improper installation can result in significant bodily harm and property damage.
• The norms and directives referred to here are valid in Germany only. In all other
countries, the national norms and directives are to be observed as amended.
• Seal the underground and cable substructure well prior to laying pipes/cables so
that the latter cannot subside.
• The nationally applicable laying and filling regulations for pipes and cables are
to be observed at all times.
Note
!
No sealing due to incorrect installation!
• Wall sleeves are to be used for all wall types except for concrete and waterproof
concrete.
• The wall must be clean, smooth, free of dust and dry in the area of the wall sleeve.
• There must be no grooves or breaks on the wall surface in the area of the wall sleeve.
• The wall sleeve must be clean and free of dust and grease.
• A clean, smooth contact surface is required for the ESH PolySafe GV1. Any existing
breaks must be reworked.
• Do not spread lubricant on the external sealing surface of the external sealing
element. The latter must be clean, dry and free of grease.
• With element and triple walls it is necessary to install Module 6 or 6.2.
• The current building waterproofing standard DIN 18533 for underground structural
components is to be observed.
• In the event of the load case "pressing water" (standing water up to 3 m) according
to DIN 18533 W2.1-E, the use of Module 1.2 is stipulated. In the event of the load
case "pressing water (standing water over 3 m) according to DIN 18533 W2.2-E,
the use of Module 4 is stipulated.
• The tightening torque is to be adapted to the type of sealing in question (see
DIN 18533, Part 1). The instructions of the waterproof membrane manufacturer
must be observed.
• If PMBC thick-film coatings are used, a sealing fleece has to be inserted between
11
the two layers of the thick-film coating. In addition, the second layer of the thick-
EN
film coating has to be protected with an EPDM supplement.
• Cables must not have any continuous grooves in the sealing area (possibly push
cable back or forwards a little until grooves are no longer visible).
• Deformed or damaged corrugated cable ducts are not suitable for sealing. They
must be trimmed or replaced.
• No cleaning agents containing solvent may be used to clean the ESH PolySafe
single-line building entry. We recommend using the cable cleaner KR M.T.X.
• For details of other accessories and further information, see www.hauff-
technik.de and the technical data sheets.
Personnel requirements
Qualifications
Risk of injury in case of inadequate qualification!
Improper handling can result in significant bodily harm and property damage.
Installation may only be carried out by qualified and trained individuals who have
read and understood these instructions.
Skilled experts
Based on their specialist training, skills, experience and familiarity with the relevant
provisions, standards and regulations, skilled experts are able to carry out the work
assigned, independently identifying and avoiding potential hazards.
Transport, packaging, scope of delivery and storage
Safety instructions in connection with transport
NOTE!
Damage in the event of improper transport!
Significant damage can occur in the event of improper transport.
When unloading packaging items on delivery and in the course of in-house transport,
proceed with care and observe the symbols on the packaging.
Transport inspection
Inspect the delivery immediately on receipt for completeness and transport damage.
In the event of transport damage being visible from the outside, proceed as follows:
• Do not accept the delivery or only do so subject to reservations.
• Make a note of the extent of damage in the transport documentation or delivery
note provided by the transporter.
Delivery scope
The ESH PolySafe GV1 single-line building entry is supplied with the following:
1 octagonal internal sealing element with sleeve pipe DN75
2 self-tapping screws 8x35
Module 4 (HRD100-FUFA) is supplied with the following:
1 fixed/loose flange for dowelling
4 wall fastenings SXR 10x80
Module 8 is supplied with the following:
1 external sealing element with membrane injection system
1 ESH support pipe (metal sleeve) as a renovation aid for breaks/uneven core
drill holes
2 anti-rotation tabs incl. 2 frame plugs
Storage
NOTE!
Damage due to improper storage!
Significant damage can occur in the event of improper storage.
• Protect the ESH PolySafe single-line building entry, sleeve caps and universal
sealing elements from damage, damp and soiling prior to installation. Only intact
components may be installed.
• The ESH PolySafe single-line building entry, sleeve caps and universal sealing elements
must be stored in such a way that they are not exposed to low temperatures (<5°
C), high temperatures (>30° C) or direct sunlight.
Disposal
If no return or disposal agreement has been concluded, recycle dismantled components
after they have been properly dismantled:
• Dispose of elastomers according to existing environmental regulations.
• Dispose of plastics according to existing environmental regulations.
• Dispose of packaging material according to existing environmental regulations.
Art. Nr.: 5090033067
Rev.: 01/2019-10-23
WARNING!
• Submit a claim for every defect as soon as it has been identified.
• Claims for damages can only be asserted within the applicable claim period.
Modules 1, 1.2, 3, 6 and 6.2 are supplied without further elements.