• Briefly press the button "ENTER/START"; the current value in the bottom line starts to
flash.
With NiCd or NiMH batteries, you can switch between manual and automatic mode
by simultaneously pressing the buttons "INC" and "DEC" (see chapter 12. a).
With lithium batteries, the cell number must also be set besides the charge current.
Change this as usual using the buttons "INC" and "DEC", confirm the value using the
"ENTER/START" button.
• If the values do not blink, you can select between the individual programs with the
buttons "INC" or "DEC". Depending on the battery type, these are "CHARGE",
"DISCHARGE", "STORAGE", "BALANCE", "CYCLE", etc.
• If you now keep the button "ENTER/START" depressed for approx. 3 seconds, all
settings are saved in the memory selected at the beginning. The display shows
"SAVE . . .".
The data in the 10 memory spaces is, of course, preserved, even if the charger is
separated from the supply voltage.
This way, you can save the data for the transmitter battery, for example (e.g. NiMH,
charge current 400mA) and for a flight battery (LiPo, 1A charge current, 3 cells).