Safety
4 Safety
4.1 Intended use
The ProDetect 2 must be used exclusively with fresh water. Dirt particles in the water can block the solenoid valve
and the sieve seal. The maximum permissible line pressure must not exceed 4 bar.
Use the ProDetect 2 only in combination with the following urinals:
Architectura 5586 / 5587 / 5574
•
Subway 7513
•
O.novo / Omnia 7507 / 7557 / 7527
•
Venticello 5504
•
Intended use also includes:
observance of all instructions in these operating instructions
•
compliance with all instructions in the installation instructions
•
compliance with the inspection and maintenance tasks
•
exclusive use of original parts
•
4.2 Reasonably predictable misuse
Any use other than those listed under "intended use", or use which goes beyond this, is considered to be non-
intended.
For damage arising from non-intended use, the operator himself is exclusively responsible, and the manufacturer
does not accept any liability whatsoever.
Care must be taken when installing the ProDetect 2 because of the limited assembly space of urinals.
Note the following instructions:
Do not crush cables
•
The sensor must be installed in the correct position and in the correct sensor direction
•
The power supply for the mains model must be installed in the correct position
•
Use only recessed sockets for installation of the mains power connection
•
Do not use surface-mounted sockets with projecting surrounds when installing the mains power connection
•
Once the urinals have been installed, no cables may hang down through the inspection shaft
•
S. 42
Important
Before opening the connected water line, you must ensure that the urinal control system
has previously been commissioned for a minimum of 30 seconds (power connection). This
applies to the battery and mains versions.