Manual part no. 717036 Ver. C
Copyright 2012 Welch Allyn
77535 - XX
GS DIAGNOSTIC DESK SYSTEM
English
Intended use
This product is intended for use In hospitals and health care facilities to
manage the storage of Welch Allyn diagnostic accessories as well as
charging these instruments.
Symbol descriptions
AC input power
DC input power
DC output power
Recycle used batteries
China RoHS markings for
properly and in
control of pollution caused
accordance with local
by electronic information
regulations. Do not
products. 10 indicates
dispose of batteries in
Environmentally Friendly
refuse containers.
Use.
Warnings and cautions
WARNING Read and understand the instructions before using this
product. Failure to understand the operating requirements for this
product can result in injury to you or the patient and can damage the
instrument.
WARNING Explosion hazard. Do not operate this product in the
presence of flammable anesthetics or other flammable substances
in combination with air, oxygen-enriched environments, or nitrous
oxide.
WARNING This is a class B product. In a medical facility this
product can cause radio interference, in which case the user might
need to take corrective measures.
WARNING Use of any accessories or materials in the GS
Diagnostic Desk System Charger (408511) not indicated in the table
below can degrade the minimum safety of the equipment.
71670
3.5V NiCad battery handle
71900/71911
3.5V Lithium Ion battery handle
04000-200
ThermoScan PRO 4000
WARNING Do not modify this equipment. Any modification of this
equipment can lead to patient injury. Any modification of this
equipment voids the product warranty.
WARNING Electric shock hazard. DO NOT autoclave the device or
accessories. The device and the accessories are not heat-resistant.
WARNING When the device is powered on, do not simultaneously
touch the contact pins and the patient.
CAUTION Only authorized Welch Allyn Service Centers can
perform service on this device.
CAUTION To make sure that the device can be unplugged from the
AC power source, never block access to the wall socket.
CAUTION Refer to manufacturers directions for use for the
diagnostic equipment.
Cleaning
WARNING Before you clean the device, unplug it from the wall
socket.
To clean the charging housing, use a damp cloth with warm water and mild
detergent or one of the following solutions:
70 percent isopropyl alcohol
10 percent mild bleach solution
Wipe dry with a clean cloth.
To clean the charging contacts inside the charging wells and on the handles
and thermometer, use a dry cloth.
Specifications
Environment
Operating:
Temperature Range
Humidity Range
Atmospheric Pressure Range
104°F
(40°C)
1060 hPa
95%
59°F
15%
(15°C)
700 hPa
Transport/storage:
Temperature Range
Humidity Range
Atmospheric Pressure Range
120°F
(50°C)
1060 hPa
95%
4°F
15%
(-20°C))
700 hPa
Safety Class II, Continuous Operation
Electrical
Power supply:
100 - 240V, 50 - 60 Hz, 0.18A Max
5V, 1 A
Charging device:
5V, 1 A
5V, 0.5 A
Additional technical information
www.welchallyn.com/gsdesksystem
Approvals
IEC 60601-1, UL 60601-1, IEC 60601-1-2, CAN/CSA C22.2 No 601.1-M90,
AS/NZS3200
N344
Welch Allyn, Inc.
Regulatory Affairs
4341 State Street Road
Representative
Skaneateles Falls, NY 13153-0220 USA
Welch Allyn Limited
Tel.: + 1 315 685 4560
Navan Business Park
Dublin Road, Navan
County Meath, Republic
of Ireland
www.welchallyn.com/weee

Warranty

One year
Guidance and manufacturer's declaration
The guidance and manufacturer's declaration information is available at
www.welchallyn.com/gsdesksystem
NOTE: This product complies with current required standards for
electromagnetic interference and should not present problems to other
equipment or be affected by other devices. As a precaution, avoid using this
device in close proximity to other equipment.
Assembly instructions
CAUTION Host USB
to be used to power
Welch Allyn approved
devices only.
25-34cm
AD
x68 max.
Charging Indicator LED
CAUTION The GS Diagnostic Desk System is supplied with a
rechargeable battery pack. To make use of the charging function,
install the rechargeable battery pack in the battery compartment of
the thermometer and then place the thermometer into the charger.
While other rechargeable batteries can be used in the thermometer,
we do not recommend it as they cannot be recharged in the Desk
Charger.
1
2
Charging Indicator LED