TROUBLESHOOTING

Problem
Check these issues
Is the air conditioner plugged in?
Is there a power failure?
The air conditioner
does not run.
Is the comp / 'full water' indicator flashing?
Is the room temperature below the set temperature?
Is there direct sunshine? (Please put down the curtain.)
Are too many windows or doors open?
The machine seems
to do little.
Are there too many people in the room?
Is there something in the room producing lots of heat?
Is the filter dusty, contaminated?
The machine seems
Is the air intake or output blocked up?
to do nothing.
Is the room temperature below your selected temperature?
Is the machine positioned unevenly so as to create vibration ?
Too noisy.
Is the floor underneath the machine uneven?
The compressor
It is possible the overheat protection of the compressor is on.
does not operate.
Just wait for the temperature to drop?
Error codes for the electrician
Code
Meaning
E1
Resin sensor on the evaporator broken down.
E2
Copper sensor on the discharge tube broken down.
E3
TC sensor is loose or broken down. Please check and replace it.
E5
Device overheated. The compressor and fan motor stop.
Press the ON/OFF button to check, if E5 signal still exists. If that is
the case, that meand dthe comprossor system is abnormal.