Operating Instructions DC 200
4 Commissioning
4.1 Connecting the device
•
Unpack the dispensing controller and set it up on a
worktable where it will be used . Preferably in a dry location .
•
Supply the dispensing unit with compressed air .
Insure that the compressed air supply is clean (5-micron filter
must be used) and dry . Condensation in the airline will
damage the unit and limit the warranty .
•
Using the airline hose supplied with the unit, connect the
compressed air inlet on the back of the dispensing unit to
your compressed air supply .
•
Connect the power cable to the power connection on back
of the unit .
•
The unit can be operated either by finger switch (sold separa-
tely), foot switch or a control cable, if the dispensing controller
is to be integrated with a dispensing robot . All these cables are
inserted into the socket for the foot switch on the back of the
unit .
•
Switch on the controller . When the Power LED is lit up, the
unit is ready for operation .
•
Seal a barrel filled with dispensing material using the barrel
adapter by placing the adapter across the barrel and then
locking it with a 90° turn .
•
Select a suitable luer lock dispensing needle and attach it
onto the barrel .
•
Connect the hose from the barrel adapter to the compressed
air outlet of the DC 200 . By turning the regulator knob in a
"clockwise" direction, make sure to end up always "bringing up"
the pressure to the desired setting to have the correct pressure
value .
17
VIEWEG
EN