temperatures. In the decants use always a funnel with filter to avoid the introduction of impurity
or silt that would prejudice the pump duration and functionality.
For the oil integral substitution proceed as follow:
Take the cylinder in rest position and empty it from oil.
Disconnect the air fed in entry.
Unscrew the plug of vent.
Upset the pump on a fit container to pick up the exhausted oil and leave drain the contained
oil.
Fill the pump with the new oil (see quantity to the chapter n°6 "Characteristic Techniques"
with special funnel.
Insert plug and clean the pump with a cloth.
Connect the air of entry and do a some cycles in going and in return.
10.3 PERIODIC CLEANING AND SUBSTITUTION OF FILTER.
Every two months of work replace the air filter, using only pieces supplied by builder. Periodic
cleaning must be made every 10 days removing the filter (unscrew up to extraction) and blowing
it with compressed air. There fore screw again, in its socket, without excessively forcing and
avoiding to break it.

11. PROBLEMS AND REMEDIES

In the following paragraph you can find some verifiable anomalies with their remedies. If,
applying all that it has been described so far, you have not solved the critical situation, consult
the builder.