The receiver gives impulses to 2 pneumatic electro-valves at 12 Volt (ON-OFF) that are
normally closed. When the receiver is in action a red led signals the operation. The receiver
gains commands transmitted by the Radio control and allows the operating of pumps.
The other constructive materials and the other particulars of which is composed the pump are
similar to which of GHIBLI model as well as the function of every piece.
A switch is placed on the Carter for the pump lighting, one as well as a bright signaller that
points out the charge of battery . The special battery charger at 220 Volt allows the
recharging when this is necessary. If required the battery charger can be furnished with a 110
Volt voltage.
7. INSTALLATION AND PUT OPERATING
The pump must be put on the floor in horizontal position. The RC and TX models can be
installed in elevated horizontal position using its special stirrups. The pump is already furnished
complete of oil.
A) CONNECTION TO THE COMPRESSED AIR.
Before connecting the discharge pipe verify that the feeding air (8 bar-116 PSI) comes from a
filter regulator endowed with slingers (to guarantee lubricated air with no impurity) It's necessary
to use a coupling which is good for the apparatus in equipment. To guarantee an air opportunity
dry, we suggest the dessictor employment on the air compressed system; such shrewdness will
make the performance of the hydraulic pumps and any other pneumatic equipment longer.
B) OIL CONNECTIONS.
The connection between pump and the use must have realized with flexible pipes and fit
couplings to bear the nominal pressure multiplied by 3. It is advised to wind the fillets with
ribbon Teflon. Make sure, in case of use of ribbon Teflon, that this doesn't obstruct the oil
passage. Tighten with care the connections and make sure that engagements are correctly
inserted.
C) VENT PLUG.
In the HPB-GHIBLI-GHIBLI RC-GHIBLI TX-SPH LT- SPH LT RC replace the hermetic plug,
with that special composed by a rod, so that it will be the possible check the oil level. This
special plug is furnished in endowment. In the model HPB RC unscrew with screwdriver the
screw that it is on the oil plug and leave free the hole for the air vent. Check the oil level using a
special rod (no supplied in endowment).

8. USE

8.1 PRUDENCE!!!

To avoid damaging the pump and the cylinder to it connected not insist to pump when the
cylinder -stem is to end run. It is advised not to bring stem to the end run but to stop it with slight
advance.
The pump employment in all versions is very simple:
8.2 EMPLOYMENT OF THE PEDAL.
Put in operate the pump pressing with the foot, without do an excessive pressure, in the zone
pointed out by letter A. The pump will begin to produce hydraulic pressure having the
driving of the destination employment through output of oil in the hydro-pneumatic circuit.
Leaving the pedal and removing the foot, the pump will stop its cycle and will remain in
pressure, leaving the employment of destination hold where it arrived .