Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Of The Outdoor Unit - McQuay G Serie Montageanleitung

Wall mounted split type air conditioner
Vorschau ausblenden Andere Handbücher für G Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
The outdoor unit must be installed in such a way, so as to
prevent short circuit of the hot discharged air or obstruc-
tion to the smooth air flow. Please follow the installation
clearances shown in the figure. Select the coolest possible
place where intake air temperature is not greater than the
outside air temperature (maximum 45°C).
Installation clearances
Dimension
Minimum Distance,
300
mm (in)
(11.8)
Note: If there is any obstacle higher than 2m, or if there is
any obstruction at the upper part of the unit, please allow
more space than the figure indicated in the above table.
B
A
C

INSTALLATION OF THE OUTDOOR UNIT

A
B
C
1000
300
(39.4)
(11.8)
D
Condensed Water Disposal of Outdoor Unit
(Heat Pump Unit Only)
There are 2 holes on the base of Outdoor Unit for
condensed water to flow out. Insert the drain elbow to
one of the holes.
To install the drain elbow, first insert one portion of the
hook to the base (portion A), then pull the drain elbow
in the direction shown by the arrow while inserting the
other portion to the base. After installation, check to
D
ensure that the drain elbow clings to base firmly.
500
If the unit is installed in a snowy and chilly area, con-
(19.7)
densed water may freeze in the base. In such case,
please remove plug at the bottom of unit to smooth the
drainage.
BASE
1-4
PLUG
A
DRAIN
DRAIN
ELBOW
ELBOW
Please remove side
plate when connect-
ing the piping and
connecting cord
PUSH & PULL UP

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis