7. Dimensions

55
Fig. 2
Dimensional sketches

8. Installation of tank

Place the tank in such a position that the cover
can be removed for periodic inspection.
To eliminate the transmission of noise to the
building,
– make sure that there is at least 10 mm
clearance between the tank and a wall
– place the tank on an anti-vibration material.
Even though a non-return valve is fitted in the
pump outlet port, the outlet pipe must be run
above the backflow level (i.e. main sewer level).
The pipes from this point must be made with pipe
sizes of at least 40 mm nominal diameter (DN
40).
We recommend that the outlet pipe travels first
vertically and then horizontally in order to utilize
the pump pressure in the vertical part of the
outlet pipe.
In order to use the connection in the tank cover
(d), knock out the disk and use the DN 40 or DN
50 fitting.
The fasteners supplied with the lifting station are
to be used for wall- or floor-mounting. See "b" in
the figure below.
Fig. 3
Installation example
405
Fig. 4
Wall or floor mounting

9. Installation of Unilift KP

Fig. 5
Unilift KP 150-A1 / KP 250-A1
Pump with float switch on the lever arm with start at
260 mm and stop at 50 mm.
b
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
b
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
‹‹
9