Herunterladen Inhalt Inhalt Diese Seite drucken

BWT AQA drink Pro 20 serie Einbau- Und Bedienungsanleitung Seite 20

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Error
Water contains too little CO
2
When the CO
button is pressed, only
2
CO
escapes
2
Flashing light at the water outlet
Water leakage
UV LED indicator flashes on the control
panel, an acoustic alarm sounds and
water cannot be dispensed
EN
38
Cause
Error recovery
CO
gas cylinder is
2
Replace the CO
gas cylinder
2
empty
Turn off the water and actuate the
CO
tank must be
CO
outlet until only gas escapes.
2
2
vented
Then turn on the water again and
allow the CO
to refill
2
Insufficient CO
pres-
2
Increase CO
pressure up to 4 bar
2
sure
Set the thermostat to a lower temper-
Temperature setting is
ature. The higher the water tempera-
too high
ture, the less CO
can be absorbed
2
Disconnect the device from the pow-
Pump does not react
er supply for 30 seconds and recon-
nect and press the CO
2
Wastewater tank is full
Empty the wastewater tank
Leakage sensor is
Contact a service technician
activated
Close the water tap, disconnect the
Water pipes in the
device from the power supply, then
device are defective
contact a service technician
Disconnect the device from the
power supply and unplug the connec-
tion; plug it back in, then switch the
UV lamp is not con-
device on again. If the UV lamp does
nected properly or is
not work, then disconnect the device
defective
from the power supply again and
replace the UV lamp. It is essential to
observe the warnings, see Section
6.4.
9. AQA DRINK PRO 20 HYGIENE CHECKLIST
Component
External hous-
ing and front
panel
Water outlet
parts
key again
Drip tray and
grid
Ventilation
slots
Water circuit
in the water
dispenser
Filter
CO
safety
2
check
UV reactor/
quartz glass
* six-monthly or when capacity is used up
** or every 2 years
Frequency of action
Type of
action
daily
weekly
six-monthly
Cleaning
Disinfection
Cleaning
Emptying
Cleaning
Disinfection
Replacement
*
Check the gas
pressure reducer
and check the
entire device
for leaks
Visual inspection
for contaminants
or cloudiness on
the quartz glass
To be performed by
annually
Customer/operating
company (remove lime
marks from the surface
of the device using a
descaling spray and
then clean and disin-
fect using a sanitary
spray)
Customer/operating
company (clean and
disinfect using a sani-
tary spray)
Customer/operat-
ing company (under
running water with
standard mild cleaner)
Customer/operating
company
Technical staff of
the distributor or
authorised, qualified
technical staff
Technical staff of
the distributor or
authorised, qualified
technical staff
Technical staff of
the distributor or
authorised, qualified
technical staff
Technical staff of
the distributor or
authorised, qualified
**
technical staff (only by
EN
competent person)
Technical staff of
the distributor or
authorised, qualified
technical staff (only by
competent person)
39

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis