Herunterladen Inhalt Inhalt Diese Seite drucken

Programming The Sprinklers Of A Sector; Programming Example - CAME TS07 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Contents
Garden: List of sprinklers
Garden-01
Garden-02
Garden-03
06:13
Wednesday 01 March 2017
3
Garden: Sprinkler configuration
B
Garden-01
06:13
Wednesday 01 March 2017
4
B
Home
Back
C
MAXIMUM IRRIGATION TIME
D
DUTY CYCLE
Home
Back

Programming the sprinklers of a sector

The list displays and lets you access the programming options for the single sprinklers that
make up the irrigation sector .
Sprinkler in stand-by,
The selection switches B can be used to activate/deactivate the single sprinklers for the
sector .
Use the cursor C to set the total operating time of the sprinkler, net of pauses .
Use the cursor D to indicate the percentage of the maximum irrigation time for irrigation and
the percentage for pauses .
Settings

Programming example

Setting a maximum irrigation time C of 30 minutes and an operating cycle of 50% D, the
irrigator is activated for 15 minutes (50% of 30 minutes), then remains in stand-by for a
further 15 minutes, after which the irrigation cycle of the second irrigator (where present)
starts, and so on for all of the irrigators in the sector .
After all of the sprinklers in the sector have finished the first part of their cycle, the sprinkler
being programmed resumes operation; it irrigates for 15 minutes (to complete the 30-minute
cycle) and remains in standby for a further 15 minutes, to finish its operating cycle .
01
30' - 50%
02
60' - 50%
Settings
Sprinkler in operation .
1 h
2 h
3 h

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ts07 wi-fiTs10Ts10 wi-fi

Inhaltsverzeichnis