(1 In relation to a rated values, the accuracy defines the maximum deviation between a set value and the corresponding actual value
Example: the 170 A model has min. 0.1% current accuracy, that is 170 mA. When adjusting the current to 10 A, the actual value is allowed to differ max. 170 mA,
which means it is allowed to be between 9.83 A and 10.17 A.
(2 At 21°C ambient temperature
EA Elektro-Automatik GmbH
Helmholtzstr. 31-37 • 41747 Viersen
Germany
EL 9080-510 B EL 9200-210 B EL 9360-120 B EL 9500-90 B
90...264 V AC
90...264 V AC
Wall socket
Wall socket
45...65 Hz
45...65 Hz
T 6.3 A
T 6.3 A
max. 130 W
max. 130 W
< 3.5 mA
< 3.5 mA
80 V
200 V
7200 W
6000 W
4500 W
4500 W
(2
510 A
210 A
0...1.03 * U
0...1.03 * U
Max
0...1.1 * I
0...1.1 * I
Max
0...1.1 * P
0...1.1 * P
Peak
88 V
220 V
approx. 2.2 V
approx. 2 V
Voltage / current: 30 ppm
0...80 V
0...200 V
< 0.05% U
< 0.05% U
Max
≤ 0.1% U
≤ 0.1% U
Max
max. 5% U
Max
0...510 A
0...210 A
< 0.1% I
< 0.1% I
Max
≤ 0.2% I
≤ 0.2% I
Max
< 23 μs
< 40 μs
< 46 μs
< 42 μs
0...P
0...P
Peak
< 0.5% P
< 0.5% P
Steady
0.015...5 Ω
0.08...28 Ω
≤1% of maximum resistance + 0.3% of maximum current