Power and Data Transmission Unit
7.8.1 IO10 module inputs
Two IO10 modules can be connected to SECUREconnect 100R via terminals LA and LB.
Input and output parameters are preset in compliance with the GU-BKS-NET concept.
Basic settings of IO10 address 1:
Input
Input 1: terminal I1, V9
Input 2: terminal I2, V9
Input 3: terminal I3, V9
Input 4: terminal I4, V9
Basic settings of IO10 address 2:
Input
Input 1: terminal I1, V9
Input 2: terminal I2, V9
Input 3: terminal I3, V9
Input 4: terminal I4, V9
7.8.2 IO10 module outputs
The input statuses (SECUREconnect 100F) are put out directly to the IO10 module relays.

Basic settings

Input
(SECUREconnect 100F)
Input 1: terminal I1, V4
Input 2: terminal I2, V4
Input 3: terminal I3, V4
Input 4: terminal I4, V4
Input
(SECUREconnect 100F)
Input 1: terminal I1, V4
Input 2: terminal I2, V4
Input 3: terminal I3, V4
Input 4: terminal I4, V4
Function
Permanent OPEN
Close
Priority locking
Priority unlocking
Function
Non-priority unlocking
-
Short-time OPEN
-
Output
IO10 address 1
Relay 1: terminal 41, 51, 61
Relay 2: terminal 42, 52, 62
Relay 3: terminal 43, 53, 63
Relay 4: terminal 44, 54, 64
Output
IO10 address 2
Relay 1: terminal 41, 51, 61
Relay 2: terminal 42, 52, 62
Relay 3: terminal 43, 53, 63
Relay 4: terminal 44, 54, 64
61 41 51 62 42 52
63 43 53 64 44 54
Service
G1 V1 LA LB
V9 I1
V9 I2
V9 I3
V9 I4
61 41 51 62 42 52
63 43 53 64 44 54
Service
G1 V1 LA LB
V9 I1
V9 I2
V9 I3
V9 I4